SNT software is unable to find any interface board

In a case of appearing error message
=Ошибка инициализации интерфейсного модуля. Возможно модуль не подключен к компьютеру или не включено питание=, please, check following:

* Agent board not powered. Tere is a "Power" indicator on a board. If it is not green (actually, off, as all other lamps on an interface board), check power path condition:

    • For boards with a 48V powering option, it should be connected to the power adapter [], that must be powered too (usually, SNT-7531, SNTlite, SNTsmart) or it should be connected to PoE? switch [], that sould provide powering for corresponding ethernet port (usually, SPIDER systems)
    • For boards with a 5V powering option, check connection to USB using USB+Ethernet-to-PoE Ethernet connector or modified USB-to-Ethernet adapter (depedns on analyzer pack specification).
  • Wrong network card configuration. SNT-7531, SNTlite, SNTsmart analyzers use TCP protocol for information exchange with a Agent-E1 boards, so IP assigning for inerface board required (it is a SNT software function). Check CTRN indication on an interface board: when flashing, interface board waiting for IP assigning. Then check network card system settings, it must conform this description.

See also:

EditorForm
ArticleStatus? Obsolete
TranslationStatus? Editing
Comment другой процесс выдачи ошибочных сообщений
Edit | Attach | Print version | History: r8 | r5 < r4 < r3 < r2 | Backlinks | Raw View | More topic actions...
Topic revision: r3 - 2007-05-29 - 12:00:35 - IlyaDanilov
 
© ООО "НТЦ Севентест". 2007. Перепечатка и копирование материалов без письменного разрешения правообладателя запрещены.
Есть идеи, вопросы или проблемы, связанные с TWiki? Свяжитесь с нами.