SNT software is unable to find any interface board
In a case of appearing error message
=Ошибка инициализации интерфейсного модуля. Возможно модуль не
подключен к компьютеру или не включено питание=, please, check following:
* Agent board
not powered. Tere is a "Power" indicator on a board. If it is not green (actually, off, as all other lamps on an interface board), check power path condition:
-
- For boards with a 48V powering option, it should be connected to the power adapter [], that must be powered too (usually, SNT-7531, SNTlite, SNTsmart) or it should be connected to PoE? switch [], that sould provide powering for corresponding ethernet port (usually, SPIDER systems)
- For boards with a 5V powering option, check connection to USB using
USB+Ethernet-to-PoE Ethernet
connector or modified USB-to-Ethernet
adapter (depedns on analyzer pack specification).
- Wrong network card configuration. SNT-7531, SNTlite, SNTsmart analyzers use TCP protocol for information exchange with a Agent-E1 boards, so IP assigning for inerface board required (it is a SNT software function). Check
CTRN
indication on an interface board: when flashing, interface board waiting for IP assigning. Then check network card system settings, it must conform this description.
See also:
Topic revision: r3 - 2007-05-29 - 12:00:35 -
IlyaDanilov